This function block of the CAA_RealTimeClock.library can be used to modify the specific information on the time zone.
The time zone setting will be kept even after a Reset Origin of the controller and can only be modified by being overwritten again. If no automatic switch is desired, all elements of „tziTimeZoneInformation.stStandardDate“ and „tziTimeZoneInformation.stStandardDate“ must be set to 0. (for further information see ⇘ RTCLK.PERIODE_INFO)
Input:
xExecute |
BOOL |
A rising edge starts the execution see: ⇘ “CAA 指南” |
tziTimeZoneInformation |
Information on time zone |
Output:
xDone |
BOOL |
Execution terminated successfully see: ⇘ “CAA 指南” |
xBusy |
BOOL |
Module active see: ⇘ “CAA 指南” |
xError |
BOOL |
Error occurred see: ⇘ “CAA 指南” |
eError |
RTCLK.ERROR |
Error ID for diagnosis (see ⇘ RTCLK.ERROR) |